Products
Health Physicists
Nuc Exp / Fallout Rescue
National Disaster
Scrap / Steel Industry
Educational institiute
Medical Institute
Radiography
 
National Disaster
National Disaster Management (NDMA) Products
.........................................................................................................................................................................................................................................................
01. Pocket Dosimeter PDM1 02. Pocket Dosimeter PDM2
03. µR Radiation Survey Meter PRM121P 04. Survey Meter Cum Dosimeter PSDM162S
05. Contamination Cum Survey Meter PCRM162D 06. Alpha Contamination Monitor ALS939
07. Contamination Monitor PCM100 08. Pedestrian/Limb Monitor PVM1
09. Vehicle Monitor PVM2 10. Portal Monitor PMS1
11. Telescopic Survey Meter TL103M 12. Counting System CS101L
13. Personal Air Sampler PAS3 14. -
15. Food Radioactivity Contamination Monitor PFC1 16. Food Radioactivity Contamination Monitor PFC3
17. Frisker for Beta/Gamma Contamination PFR1 18. Area Gamma Monitor PAM452
19. NA 20. NA
Please click on a specific Model Number below, to display the detailed catalog of that product, in Adobe Acrobat PDFPDF format
.........................................................................................................................................................................................................................................................
You can use the 'Text Select Tool' from within acrobat reader to select the required block of text & paste it into any other application in plain-text format.
..........................................................................................................................................................................................................................................................


       Pocket Dosimeter PDM1

Range: 1µSv to 999999µSv
Compact Design - 90 x 45 x 12mm
Light Weight - 50gms
Drop Protection
No False Dose due to Mobile / Radar Signals
No False Dose due to Tapping or Impacts
Properly measures Dose even under effect of
Continuous Mobile Data

Scroll to Top


       Pocket Dosimeter PDM2

Range: 1µSv to 999999µSv
Compact Design - 90 x 45 x 12mm
Light Weight - 50gms
Drop Protection
No False Dose due to Mobile / Radar Signals
No False Dose due to Tapping or Impacts
Properly measures Dose even under effect of
Continuous Mobile Data

Scroll to Top


       µR Radiation Survey Meter PRM121P

Portable instrument to detect minute radioactive material
1µR to 200mR/hr (5 Ranges)
Plastic Scintillator detector
Analog Meter & Illuminated Scale
HV check, Battery check

Scroll to Top


       Survey Meter Cum Dosimeter PSDM162S

Pocket size survey meter cum dosimeter
Microcontroller Based
Backlit LCD display
Dose upto 10R & 100mSv
Doserate from 1µR/hr to 500mR/h
Doserate from 0.01µSv/hr to 5mSv/hr
Can be opearated on Rechargeable Batteries

Scroll to Top


       Contamination Cum Survey Meter
       PCRM162D

Microcontroller Based
CPS, CPM & Bq/cm2
0.00 to 200 mR/hr
0.0 µSv/hr to 2 mSv/hr
Rechargeable Battery
 

Scroll to Top


       Alscin Wall Monitor ALS939

SPECIAL THIN HONEY-COMB PATTERN S.S. MESH
FOR BETTER EFFICIENCY AND LARGE OPEN AREA
MICRO CONTROLLER BASED
HAND HELD, LIGHT WEIGHT & PORTABLE
AUTOMATIC CONVERSION TO bq/cm2 ,CPS,CPM
EASY REPLACEMENT OF ALUMINISED MYLAR
WELL PROVEN LONG LIFE PM TUBE
DATA STORAGE & DUMP VIA RS232 PORT

Scroll to Top


       Contamination Monitor
       PCM100

Detects Alpha & Beta simultaneously
16 x 2 Backlit LCD
Alpha to Beta Crosstalk < 10%
Beta to Alpha Crosstalk < 1%
Mylar protection using honey-comb design S.S. mesh
Screwless Mylar replacement
9V rechargeable battery
9999 CPS, 999999 Counts

Scroll to Top


       Pedestrian/Limb Monitor PVM1

For monitoring minute radioactivity carried by a person or package. Serves as gate monitor
Detects minute 1µCi Co60 or 2.5µCi Cs137 contamination from a distance of 0.5m within 1 or 2sec
Detector : Plastic Scintillator
Audio-Visual Alarm, Control room indication
Can control turnstyle gate

Scroll to Top


       Vehicle Monitor PVM2

For monitoring radioactivity in truck/container
Detects minute 4µCi Co60 contamination from a distance of 1.25m within 1 or 2sec
Detector : Plastic Scintillator
Audio-Visual Alarm, Control room indication
Can control gate

Scroll to Top


       Portal Monitor PMS1

Microcontroller Based
Data Storage, Serial Port
Backlit LCD display (16 x 2)
Sensitivity: 200gm Unat or 20Kbq Co-60 or 37Kbq Cs-137 within 1sec
Pancake Probe
Date & Time Stamping (optional)

Scroll to Top


       Telescopic Survey Meter TL103M

For high range radiation levels monitoring, upto 1000R/hr
Detector probe extends upto 4 meter
Quick Extension / Retraction to meet emergency needs
Rugged Stainless Steel 9-section Telescope
Battery Voltage Measurement to check serviceability prior to use
Autoranging
 

Scroll to Top


       Counting System CS101L

Used for offline contamination checking from the dried liquid drop or dust or air
Designed For Gross Counting of Alpha or Beta/Gamma
999999 counts & 9999 sec time settings
Large LCD Display

Scroll to Top



       Personal Air Sampler PAS3

1 to 3 LPM
Built-in Flow rate Indicator
Compact Re-Chargeable Battery Operated
Timer
Samples air dust on filter paper

Scroll to Top


       Food Radioactivity Contamination Monitor
       PFC1

Simple to use
Low Cost
NaI Scintillator Detector
Portable, Battery operated
Detects even minute contamination
  For Emergency use

Scroll to Top


       Food Radioactivity Contamination Monitor
       PFC3

Low Cost
Easy to find presence of Gamma radioactivity
Easy to judge extent of contamination
Built-in 250 Channel automatic SCA
Data Storage & Printing
  Isotope Identification either manually or via PC

Scroll to Top


       Frisker for Beta/Gamma Contamination
       PFR1

Audio Chirps
LED for Visual Indication
Battery Operated
40cm long stick

Scroll to Top


       PAM452

NAME Area Gamma Monitor
RADIATION Gamma
RANGES 0.01 - 99.99mR/hr
DISPLAY 4 digit 0.5" LED seven segment
DETECTOR Internal GM Tube with energy compensation.
FACILITIES Microcontroller based, Quick response, Digital Alarm Setting, Alarm output via relay contacts, RS485/Ethernet Interface, MODBUS TCP/RTU protocols, Suitable for SCADA

Scroll to Top

NOTE: Some of the facilities mentioned above may be optional, at an extra cost.